The China's Leading 

Heating Element Manufacturer

    • Type J Thermocouple: The type J is also very common. It has a smaller temperature range and a shorter lifespan at higher temperatures than the Type K. It is equivalent to the Type K in terms of expense and reliability.

       

      Type J Temperature Range:

      Working temperature of J Type Thermocouple is 32 to 1382F(0 to 750°C)

      Extension wire, 32 to 392F (0 to 200C)

       

      Type J Accuracy (whichever is greater):

      Standard: +/- 2.2C or +/- .75%

      Special Limits of Error: +/- 1.1C or 0.4%

       

      Consideration for bare wire type J thermocouple applications:

      The Type J Is Well Suited To Oxidizing Atmospheres

      Type K Thermocouple (Nickel-Chromium / Nickel-Alumel): The type K is the most common type of thermocouple. It’s inexpensive, accurate, reliable, and has a wide temperature range. The type K is commonly found in nuclear applications because of its relative radiation hardness. Maximum continuous temperature is around 1,100C.

       

      Type K Temperature Range:

      Type K Thermocouple Grade WireThermocouple grade wire, –454 to 2,300F (–270 to 1260C)

      Extension wire, 32 to 392F (0 to 200C)

       

      Type K Accuracy (whichever is greater):

      Standard: +/- 2.2C or +/- .75%

      Special Limits of Error: +/- 1.1C or 0.4%

      Type N Thermocouple (Nicrosil / Nisil): The Type N shares the same accuracy and temperature limits as the Type K. The type N is slightly more expensive. The type N has better repeatability between 572F to 932F (300C to 500C) compared to the type K.

       

      Type N Temperature Range:

      Maximum continuous operating temperature: up to 2,300F (1,260C)

      Type N Thermocouple Grade WireShort term use: 2,336F (1,280C)

       

      Extension wire, 32 to 392F (0 to 200C)

       

      Type N Accuracy (whichever is greater):

      Standard: +/- 2.2C or +/- .75%

      Special Limits of Error: +/- 1.1C or 0.4%

      Consideration for bare wire type E thermocouple applications:

      The type N holds up better to oxidation at high temperatures when compared to the type K.

       

      Type T Thermocouple (Copper/Constantan): The Type T is a very stable thermocouple and is often used in extremely low temperature applications such as cryogenics or ultra low freezers. It is found in other laboratory environments as well. 

       

      Type T Temperature Range:

      Working temperature of J Type thermocouple is 32 to 662F(0 to 350C)

      Extension wire, 32 to 392F (0 to 200C)

       

      Type T Accuracy (whichever is greater):

      Standard: +/- 1.0C or +/- .75%

      Special Limits of Error: +/- 0.5C or 0.4%

      Consideration for bare wire type T thermocouple applications:

      The Type T Is Well Suited To Oxidizing Atmospheres

      • A wire from the sensing point to the thermocouple point to measure the temperature of the signal.Thermocouples are sensors that measure temperature, which are made of two different metals that are connected at the induction end.Different thermocouples use different metal mixtures in wire.The millivolt supplied by the thermocouple represents the difference in the temperature of the induction terminal compared .

         

        Product Description

         

        SIZE CHART

        Application

        1. Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable

        for thermocouple type K, J, E, T, N and L and other high temperature detection instrument,

        temperature sensor, etc.

        2. Compensating wire level (low temperature level). This type of thermocouple wire is mainly suitable

        for compensating cable and extension wire of various thermocouples of type S, R, B, K, E, J, T and N , heating cable, control cable and so on.

         

      • Characteristics VS Properties :

        These flexible ceramic pad heaters are designed for most preheat and post heat treatment (stress relieving) requirements on weld joined materials. They can be used to construct a simple, inexpensive furnace when combined with the proper insulation as well as in many other applications where a flexible heater is required.

        These flexible ceramic pad heaters are designed for most preheat and post heat treatment (stress relieving) requirements on weld joined materials. They can be used to construct a simple, inexpensive furnace when combined with the proper insulation as well as in many other applications where a flexible heater is required.

        Flexible Heater Type is a pad heater constructed of interlocking sintered alumina ceramic beads which insulate stranded nickel-chrome wire. This durable construction forms a flexible mat of considerable mechanical strength. They can be used up to 2050°F (1121°C) and are supplied with insulated leads with male welder terminations.

        Information

    • Due to their location in often adverse environments such as hot working zones of furnaces and machinery, temperature sensors are liable to corrosion and mechanical damage. The need for occasional replacement is inevitable and the use of suitable connectors permits error-free fast, positive and reliable interchange with no risk of dangerous cross connection.

      These thermocouple plugs and sockets have a technical and practical advantage over other types when terminating thermocouple wires or compensating cable in a wide variety of sizes. The wires are sandwiched between plates of thermocouple compatible material with a clamping screw, accommodating from very fine wires to stranded cables (up to 0.75mm2). The connectors are colour coded and polarised and will mate with other makes of plugs and sockets.

      They can be mounted directly on to sheaths of up to 3mm diameter in the case of the miniature version or 1/4” (6.35mm) with the standard version by means of the brass bush available. The sockets can be supplied as in-line or panel mounting versions with rectangular or circular fascias. The connectors are ruggedly made of glass filled thermoplastic for reliable operation up to 220°C sustained temperature. The use of thermocouple compatible material eliminates measurement error due to the interconnection and the bright ISA colour coded body ensures clear identity of the type of thermocouple in use.

      • Miniature and standard connectors

      • Compensated connections ensure high accuracy

      • Types K, J, T, E, N, or Copper

      • Compatible with all other makes of equivalent connectors

      • Withstand high temperature, 220°C continuous

      • Rugged construction

      • In line or panel mounting connectors, single or multi-way

      • Inexpensive

      • PCB mounting available